SW Tee

Socket-Welding Fittings – Tees
Nominal
Pipe Size
Socket Bore Diameter, B
Bore Diameter of Fittings, D
Socket Wall Thickness, C
[Note (2)]
Body Wall,
G
Min. Depth of Socket,
J
Center to Bottom of Socket, A
Tolerances, ±
Class Designation Class Designation Class Designation Class Designation
3000 6000 9000 3000 6000 9000 3000 6000 9000
3000
6000
9000
A
Min. Max. Min. Max. Min. Max. Min. Max. Avg. Min. Avg. Min. Avg. Min. Min. Min. Min.
1 ⁄ 8 10.80 11.20 6.10 7.60 3.20 4.80 . . . . . . 3.18 3.18 3.96 3.43 . . . . . . 2.41 3.15 . . . 9.50 11.00 11.00 . . . 1.00
1 ⁄ 4 14.20 14.60 8.50 10.00 5.60 7.10 . . . . . . 3.78 3.30 4.60 4.01 . . . . . . 3.02 3.68 . . . 9.50 11.00 13.50 . . . 1.00
3 ⁄ 8 17.60 18.00 11.80 13.30 8.40 9.90 . . . . . . 4.01 3.50 5.03 4.37 . . . . . . 3.20 4.01 . . . 9.50 13.50 15.50 . . . 1.50
1 ⁄ 2 21.80 22.20 15.00 16.60 11.00 12.50 5.60 7.20 4.67 4.09 5.97 5.18 9.35 8.18 3.73 4.78 7.47 9.50 15.50 19.00 25.50 1.50
3 ⁄ 4 27.20 27.60 20.20 21.70 14.80 16.30 10.30 11.80 4.90 4.27 6.96 6.04 9.78 8.56 3.91 5.56 7.82 12.50 19.00 22.50 28.50 1.50
1 33.90 34.30 25.90 27.40 19.90 21.50 14.40 16.10 5.69 4.98 7.92 6.93 11.38 9.96 4.55 6.35 9.09 12.50 22.50 27.00 32.00 2.00
1-1⁄4 42.70 43.10 34.30 35.80 28.70 30.20 22.00 23.50 6.07 5.28 7.92 6.93 12.14 10.62 4.85 6.35 9.70 12.50 27.00 32.00 35.00 2.00
1-1⁄2 48.80 49.20 40.10 41.60 33.20 34.70 27.20 28.70 6.35 5.54 8.92 7.80 12.70 11.12 5.08 7.14 10.15 12.50 32.00 38.00 38.00 2.00
2 61.20 61.70 51.70 53.30 42.10 43.60 37.40 38.90 6.93 6.04 10.92 9.50 13.84 12.12 5.54 8.74 11.07 16.00 38.00 41.00 54.00 2.00
2-1⁄2 73.90 74.40 61.20 64.20 . . . . . . . . . . . . 8.76 7.67 . . . . . . . . . . . . 7.01 . . . . . . 16.00 41.00 . . . . . . 2.50
3 89.80 90.30 76.40 79.40 . . . . . . . . . . . . 9.52 8.30 . . . . . . . . . . . . 7.62 . . . . . . 16.00 57.00 . . . . . . 2.50
4 115.20 115.70 100.70 103.80 . . . . . . . . . . . . 10.69 9.35 . . . . . . . . . . . . 8.56 . . . . . . 19.00 66.50 . . . . . . 2.50

 

GENERAL NOTE: Dimensions are in millimeters.
NOTES: Average of socket wall thickness around periphery shall be no less than listed values. The minimum values are permitted in localized areas.